Installing internal SCSI drives with active termination
An internal SCSI hard disk can give an X68000 useful capacity while retaining the machine’s original form. Installation is often mechanically simple, but the controller, bus width, connector, target ID and termination must all agree before the drive is powered. The bus must be terminated deliberately at the correct physical locations, not patched together with an improvised resistor pack.
X68000 models and revisions are not interchangeable. Some storage arrangements use SASI or IDE, while SCSI appears on particular machines and expansion hardware. Check the controller documentation, connector beside the drive bay and existing termination jumpers. A 3.5-inch disk may still require a 50-pin IDC ribbon, a different voltage or an adapter the original controller cannot negotiate.
Restoration often combines original boards with modern storage and tired power supplies. Before buying parts, inventory the host adapter, internal cable, rear connectors and bay hardware, then photograph the original layout. Record any existing target IDs and termination settings. This evidence is more reliable than assumptions carried over from an external-SCSI setup or another X68000 revision.
Australian sourcing affects the build. Sydney and Melbourne dealers, collectors and eBay Australia sellers offer adapters, cable and replacement supplies, while Japanese auctions can provide NOS disks and period controller boards. Imports may attract 10% GST, duty and handling through Australian Customs/ABF, making the landed cost more than advertised. One tested drive is usually a safer purchase than several untested units.
Check the X68000 SCSI hardware
Begin with the host adapter, not the disk. Identify its model, SCSI standard, supported bus width and termination scheme from the silkscreen or service manual. Narrow eight-bit, single-ended SCSI is common in original installations. A Wide or LVD drive must not be connected to a narrow connector, and jumper changes cannot make incompatible electrical standards work.
Map the bus next. Internal narrow-SCSI paths normally use a 50-pin high-density IDC connection, sometimes adapted from the 25-pin Centronics socket used by external devices. Follow the signal path through every target and note where the chain physically ends. The host normally occupies SCSI ID 7; target IDs 0 through 6 may be available, subject to the adapter’s configuration.
Inspect termination before opening the case. Host boards often include active termination at the controller end, while a peripheral may have a removable passive network for the far end. Some compact designs use one integrated arrangement, but only the controller manual can confirm that exception. Software emulation can help identify the expected boot environment; the site’s guide to Raspberry Pi FPGA emulation is a useful starting point, though only the real bus can confirm termination behaviour.
Choose a compatible internal drive
Choose a disk that matches the whole chain, not merely the bay size. It must support the adapter’s electrical standard, termination method and command set, and its capacity must be usable by the X68000 disk tools or controller firmware. Modern disks may need geometry translation or a later utility if the original setup can see only its original capacity.
The local market provides both adapters and original Japanese parts, but condition varies. Melbourne collectors and specialist sellers may have SCSI interface boards or recreated cables, while Sydney buyers commonly find used disks through eBay Australia. Listings that merely say “working” reveal little; ask for photographs, a spin-up recording, jumper settings and the return terms for a private purchase.
Check the drive’s rear for termination, write-protect, parity and spin-up jumpers. Record the factory SCSI ID before moving anything, because an unfamiliar disk set to ID 0 may collide with the boot target. Delayed spin-up can help noisy systems but may exceed what an older controller expects during boot. Follow the manufacturer’s jumper table rather than another drive’s photograph.
Configure IDs and active termination
Select one unused target ID and confirm it from the controller’s diagnostics or jumpers. The usual narrow-SCSI rule is seven targets numbered 0 to 6 and a host ID of 7, but duplicates cause intermittent faults that resemble bad media. Daisy-chain order should follow the controller documentation, with the final physical device handling termination as that scheme requires.
Active termination uses a powered resistor network that holds data lines at a stable voltage with less bus loading than a passive network. It normally draws from TERMPWR on the SCSI connector. Some adapters supply that power and others do not; a few also require termination to be enabled by jumper. Never power the terminator from an improvised external supply, and use the resistor arrangement specified for the host adapter.
| Termination choice | Electrical behaviour | Suitable placement | Main caution |
|---|---|---|---|
| Active | Uses TERMPWR to maintain defined signal voltages | At an endpoint required by the host-adapter design | Do not combine it with passive termination at the same end |
| Passive | Uses an unpowered resistor network, commonly 220 ohms per line | Only where the controller documentation specifies it | Check the exact network and its enabled position |
| Unterminated | Leaves the bus without endpoint bias | Not a normal operating configuration | Reflections can cause intermittent errors and corrupted data |
Older narrow devices often use a passive 220-ohm-per-line network at the far end, and some proven adapters pair that network with active host termination. If the new disk offers an active switch, remove its passive network and use only one method at that end. If another disk already terminates the chain, disable it and relocate termination to the new physical end. Duplicate or mid-bus termination can corrupt data.
Fit the drive and connect the ribbon
Disconnect mains and the X68000 supply, and treat the CRT and PSU as live until discharged by a technician. Photograph the existing cable route and switch settings. Fit the disk to its 3.5-inch cradle with the correct face orientation, using original screws or standoffs where possible. A loose mount can transmit vibration and make an intermittent bus resemble a failing drive.
Connect the 50-pin ribbon only after checking every pin-one mark. An IDC socket can appear seated when the cable is offset by one row, so do not force it; inspect the key from a low angle. Keep the internal run short and clear of sharp edges. If the controller has a pass-through connector, route the outbound cable directly to the next device.
With power off, trace the chain to the planned final terminator and ensure no intervening disk has termination enabled. Check host-side termination separately. Inspect the ribbon for folds, crushed contacts or a one-row misfit. This visual check catches more installation faults than repeated filesystem tests and costs nothing.
Connect power safely for Australian use
Use the drive’s documented power connector and verify orientation against the X68000 supply or adapter documentation; wire colour alone is not a guide. Confirm 5-volt and 12-volt availability, current headroom and spin-up behaviour. Active termination power travels through the SCSI bus and is separate from motor power. A healthy 5-volt rail does not prove that TERMPWR is present.
Australia’s 230-volt mains makes voltage checking essential. Many Japanese X68000 supplies were designed for 100 volts and must not be connected directly to Australian outlets; use a correctly rated isolated arrangement or a professionally restored local supply. Any replacement supply sold here must meet applicable Australian electrical safety and RCM requirements. Have an original PSU inspected before it powers a replacement disk.
Temperature and transit also matter. Brisbane and Sydney summers can push ambient air above 30°C, while a crowded X68000 case has little cooling for a spinning disk. Preserve airflow, keep drives clear of the PSU and monitor temperature if the controller permits. For Australian Post or courier shipping, use anti-static protection and a moisture barrier, then let the drive acclimatise before opening it.
Configure software and test the disk
Power the controller and use its diagnostic or configuration utility to list the SCSI bus before formatting anything. A visible target ID, expected capacity and successful inquiry response are better evidence than spindle sound. If the target is absent, check ID conflicts, connector orientation, host termination and TERMPWR before changing the disk’s own termination setting.
Create a small test partition with an X68000-compatible formatter or Human68k disk utility supplied for that controller, then test the full device. Older systems may impose geometry limits, so a modern desktop partition scheme is not a safe substitute. Back up the original files and boot environment before writing, and keep the replacement unformatted until the controller has recognised it reliably.
After low-level tests, copy representative files, verify them with a checksum and run a sustained read benchmark. Repeat after a warm restart and, where practical, a full power cycle. Put the new target in the boot path only if its ID and boot sector are supported. Seek noise, vibration or disappearing IDs mean stopping to inspect the ribbon and termination, not repeatedly rewriting the filesystem.
Preserve the installation and help others
Document the result while details are fresh: controller model, drive model, SCSI ID, jumper positions, termination method, cable route and firmware settings belong in one record. Clear photographs of switch settings and rear connectors are more useful than a note saying “as shown”. Administrators preserving the same material in SharePoint can also use SharePoint deployment notes to organise versioned records and backups.
X68K.net provides a natural home for this material alongside notes on the Nereid-X board, power-supply restoration, hardware modification and emulation. Include photographs of the original and finished arrangements, exact part numbers and deviations from the manual. Japanese terminology helps when searching for scarce parts, while English descriptions make the record useful across the wider X68000 community.
Choose one verified drive, complete the build and publish the settings and test results on X68K.NET or in an Australian retro-computing group. A carefully recorded termination arrangement, even one adapted to a particular revision, can spare another restorer from damaged data and keep the platform in active use.
Nereid-X Expansion Board
A personally-produced LAN+USB+Memory expansion board for Sharp X68000 series computers. Multiple production runs were offered, including a final batch and a later revival reproduction run.
Power Supply Repair
X68 power supply repair and modification services were offered by the site owner, with documentation shared through diary entries spanning 2001–2006.
Server & Networking
Notes on FreeBSD administration, ISP changes, server migration, and networking topics. The site itself ran on FreeBSD with the hns diary system and Namazu search integration.
Get in touch
X68K.NET connects Sharp X68000 enthusiasts through community links and shared projects. Reach out with questions about the Nereid project or X68 resources.